| Specifications |
|
|
|
Power Input |
Natural Gas: 28,000 - 117,000 Btu LP Gas: 28,000 - 117,000 Btu |
|
Minimum Flow to Activate |
0.5 gallons per minute (gpm) |
|
Flow Rates |
50°F rise @ 3.6 gpm 55°F rise @ 3.3 gpm 65°F rise @ 2.8 gpm 75°F rise @ 2.4 gpm 90°F rise @ 2.0 gpm |
|
Energy Factor |
NG: .69 LP: .79 |
|
Thermal Efficiency |
NG: 80% LP: 86% |
|
Dimensions |
Height: 29.75" Width: 18.25" Depth: 8.75" |
|
Weight |
44 lbs. |
|
Modulating Gas Valve |
Yes |
|
Ignition |
Standing Pilot |
|
|
|
| Installation Specifications |
|
|
| Gas Connections |
¾" Male NPT |
| Water Connections |
½" Male NPT |
| Natural Gas Pressure |
Minimum: 7" WC Maximum: 14" WC |
| LP Gas Pressure |
Minimum: 11" WC Maximum: 14" |
| Water Pressure |
Minimum: 18 PSI Maximum: 150 PSI |
| Electrical Supply |
None |
| Vent Termination |
Vertical |

|
|
|
|
|
| | Ref. | Description | Min. Distance |
|
| A, B, C | Directly below or from an opening; operable windows, doors and any fresh air openings | 4 ft. |
|
| D | From any adjacent wall or shrubery | 4 ft. |
|
| E | Below a gutter, sanitary pipework, eaves or overhang | 3 ft. |
|
| F | Above ground | 1 ft. |
|
| G | From a gas meter or gas regulator | 3 ft. |
|
|
|
|
|
|
| |
|
| |
|
| |